Certification

Explosion proof ATEX IECEx

112G Exd IIC T6-T3 Gb

112D Extb IIIC T85˚C Db

Power Supply - 15 to 30vDC 24v nominal

Outputs - 3 wire 4~20mA / 4 wire CANbus

Relays - Low alarm S.P.C.O / High alarm S.P.C.O / Fault alarm S.P.C.O

Rating - 0.5A @30vDC

Inhibit option during servicing

Logging - Intervals - one minute to one hour / Storage - 2,880 readings

Display - 2 line alpha numeric back lit status display: gas type, concentrating units, alarm levels, alarm status, low/high/over range), sensor ID, inhibit

Indicators - Alarm - Red LED / Fault - Amber LED (flashing when in inhibit)

Housing Material - Copper free aluminium alloy, optional stainless steel

Finish - Chemical resistant epoxy paint / Optional - Marine grade finish / Sensor material - Stainless Steel 316516

Ingress Protection - IP63 + weather shield IP65

Cable Entry - 2 x M20 - 1.5 pitch - alternatives 25mm - 3/4 NPT

Weight - 1.6kg

Temperature -15˚C to +55˚C

See certification for Exd use

Humidity - 0 to 99% RH non-condensing

"> XDI-F1 Win
background

XDI-F1 Win

XDI-F1 Win
3 Reviews

Certification

Explosion proof ATEX IECEx

112G Exd IIC T6-T3 Gb

112D Extb IIIC T85˚C Db

Power Supply - 15 to 30vDC 24v nominal

Outputs - 3 wire 4~20mA / 4 wire CANbus

Relays - Low alarm S.P.C.O / High alarm S.P.C.O / Fault alarm S.P.C.O

Rating - 0.5A @30vDC

Inhibit option during servicing

Logging - Intervals - one minute to one hour / Storage - 2,880 readings

Display - 2 line alpha numeric back lit status display: gas type, concentrating units, alarm levels, alarm status, low/high/over range), sensor ID, inhibit

Indicators - Alarm - Red LED / Fault - Amber LED (flashing when in inhibit)

Housing Material - Copper free aluminium alloy, optional stainless steel

Finish - Chemical resistant epoxy paint / Optional - Marine grade finish / Sensor material - Stainless Steel 316516

Ingress Protection - IP63 + weather shield IP65

Cable Entry - 2 x M20 - 1.5 pitch - alternatives 25mm - 3/4 NPT

Weight - 1.6kg

Temperature -15˚C to +55˚C

See certification for Exd use

Humidity - 0 to 99% RH non-condensing

    Key Features:
  • Explosion proof
  • Rugged and reliable
  • 3 alarm points
  • CANbus 4~20mA outputs
  • Wide range of gas types / sensors
  • Non intrusive adjustment magnets
  • Back lit alpha numeric full status display
  • Addressable or stand alone
  • Hyper terminal communications / RS232 - live data and
  • set up with 232 adapter
  • One man calibration
  • 2 alarm relays plus fault relay or 3 alarm relays
  • Data logging
Add A Review